Transfected Stable Cell Lines
Reliable | High-Performance | Wide Rage
Precision reporter, kinase, immune receptor, biosimilar, Cas9, and knockout stable cell lines for diverse applications.
Cat. No. : CSC-RR00996
Host Cell : HCC4006 Size : >1x106 frozen cells/vial
| Cat. No. | CSC-RR00996 |
| Description | HCC4006-GFP/Luc cell line is engineered to co-express GFP and luciferase reporter genes in HCC4006 cells. GFP and luciferase are useful biomarkers and are widely used in cell research to label and monitor various types of cells. This cell line is a powerful tool in both fluorescent and bioluminescent tracking of HCC4006 cells. |
| Product Type | Stable cell line expressing GFP and luciferase reporter genes |
| Target Gene | GFP/Luc |
| Host Cell | HCC4006 |
| Host Cell Species | Homo sapiens (Human) |
| Applications |
1) in vitro cell tracking by both the fluorescent and bioluminescent signal 2) monitor in vivo tumor growth using both the fluorescence and bioluminescence signal 3) anticancer drug development |
| Size | One vial of frozen cells, typically >1x10^6cells/vial |
| Stability | This cell line is stable at least 10 passages. |
| Quality Control |
1) fluorescence detection under microscopy 2) in vitro cell luciferase assay 3) mycoplasma detection |
| Storage | Liquid nitrogen |
| Shipping | Dry ice |
| Revival | Rapidly thaw cells in a 37°C water bath. Transfer contents into a tube containing pre-warmed media. Centrifuge cells and seed into a 25 cm2 flask containing pre-warmed media. |
| Growth Properties | Adherent |
| Mycoplasma | Negative |
| Format | One frozen vial containing millions of cells |
| Storage | Liquid nitrogen |
| Safety Considerations |
The following safety precautions should be observed. 1. Use pipette aids to prevent ingestion and keep aerosols down to a minimum. 2. No eating, drinking or smoking while handling the stable line. 3. Wash hands after handling the stable line and before leaving the lab. 4. Decontaminate work surface with disinfectant or 70% ethanol before and after working with stable cells. 5. All waste should be considered hazardous. 6. Dispose of all liquid waste after each experiment and treat with bleach. |
| Ship | Dry ice |
The HCC4006 cell line is a well-established human model of non-small cell lung cancer (NSCLC), originally isolated from the pleural effusion of a patient with metastatic lung adenocarcinoma. It is highly valued in pulmonary oncology for harboring an endogenous activating deletion in exon 19 of the epidermal growth factor receptor (EGFR) gene, making it a critical preclinical tool for studying EGFR-driven malignancies. The GFP/Luc Reporter Cell Line - HCC4006 is a sophisticated, stably transfected derivative engineered to simultaneously co-express both Green Fluorescent Protein (GFP) and firefly luciferase (Luc). This robust dual-labeling construct ensures consistent, high-level expression of both functional reporter genes across sequential in vitro passages. Crucially, this genetic integration is achieved while rigorously preserving the fundamental biological properties, the unique mutational profile, and the intrinsic tumorigenic capacity of the original parental HCC4006 cells.
The incorporation of this dual-reporter system significantly expands the analytical capabilities of the HCC4006 model for translational respiratory research. In vitro, the distinct GFP tag enables researchers to easily monitor cellular morphology, quantify proliferation rates, and isolate specific subpopulations using standard fluorescence microscopy and flow cytometry. For in vivo studies, the strong luciferase expression provides the optimal foundation for non-invasive, longitudinal tracking of primary tumor progression and metastatic spread through bioluminescence imaging (BLI). Because it is a human-derived cell line, the HCC4006-GFP/Luc model is typically engrafted into immunocompromised mice (such as athymic nude or NSG strains) to establish localized subcutaneous xenografts or orthotopic lung models. This specialized reporter line serves as an indispensable platform for evaluating the therapeutic efficacy of targeted pharmacological compounds, particularly EGFR tyrosine kinase inhibitors (TKIs), and for studying mechanisms of acquired drug resistance. By facilitating the real-time, accurate quantification of tumor burden in living subjects, it greatly accelerates preclinical discoveries in precision lung oncology.
If your question is not addressed through these resources, you can fill out the online form below and we will answer your question as soon as possible.
We were impressed by the quality of the GFP/Luc Reporter Cell Line - HCC4006. The cells showed excellent viability after thawing, and reporter expression remained stable during extended culture. This product has greatly supported our targeted therapy research efforts.
Write a review of your use of Biogene products and services in your research. Your review can help your fellow researchers make informed purchasing decisions.