NFAT-Luc/KDR Stable Cell Line - HEK293T

NFAT-Luc/KDR Stable Cell Line - HEK293T

Cat.No. :  CSC-RR0541 Host Cell:  HEK293T

Inquire for Price

Cell Line Information

Cell Culture Information

Safety and Packaging

Cat. No. CSC-RR0541
Description This cell line is engineered to co-express human KDR and luciferase reporter gene under the control of NFAT response element.
Gene NFAT-Luc/KDR
Host Cell HEK293T
Host Cell Species Homo sapiens (Human)
Stability Validated for at least 10 passages
Application

1. Gene expression studies

2. Protein localization

3. Drug screening and toxicology

4. Live cell imaging

Quality Control Negative for bacteria, yeast, fungi and mycoplasma.
Shipping Dry ice
Storage Liquid nitrogen
Revival Rapidly thaw cells in a 37°C water bath. Transfer contents into a tube containing pre-warmed media. Centrifuge cells and seed into a 25 cm2 flask containing pre-warmed media.
Growth Properties Cells are cultured as a monolayer at 37°C in a humidified atmosphere with 5% CO2. Split at 80-90% confluence, approximately 1:3-1:6.
Mycoplasma Negative
Format One frozen vial containing millions of cells
Storage Liquid nitrogen
Safety Considerations

The following safety precautions should be observed.

1. Use pipette aids to prevent ingestion and keep aerosols down to a minimum.

2. No eating, drinking or smoking while handling the stable line.

3. Wash hands after handling the stable line and before leaving the lab.

4. Decontaminate work surface with disinfectant or 70% ethanol before and after working with stable cells.

5. All waste should be considered hazardous.

6. Dispose of all liquid waste after each experiment and treat with bleach.

Ship Dry ice
Quick Inquiry

Background

Applications

Publications

Q & A

Customer Reviews

NFAT-Luc/KDR Stable Cell Line - HEK293T is a unique and powerful tool designed for analyzing NFAT (nuclear factor of activated T cells) activity and studying KDR (kinase insert domain receptor) related functions. This cell line was genetically engineered from the human embryonic kidney 293T line to stably integrate a luciferase reporter gene under the control of an NFAT response element. The NFAT transcription factor plays a crucial role in immune response, heart valve development, blood vessel development, and various other physiological processes. KDR, also known as VEGFR-2, is a major transducer of VEGF-mediated signals within the cardiovascular system, making this cell line highly beneficial for research in these areas. The presence of a luciferase reporter gene in this cell line allows for convenient detection and measurement of intracellular NFAT-dependent transcriptional activity. This makes the NFAT-Luc/KDR stable cell line – HEK293T very useful for high-throughput screening applications, drug discovery and development, and for fundamental understanding of NFAT and KDR biology.
NFAT-Luc/KDR stable cell line - HEK293T is a very useful tool in scientific research, especially in the fields of cell biology and drug discovery. Here are some possible applications: Drug Screening and Discovery: This cell line is valuable for screening and evaluating potential drugs that modulate KDR or NFAT activity. This includes testing the effectiveness of new drugs or studying the resistance mechanisms of cancer cells. Studying NFAT Activation: Researchers can use this cell line to study the process of NFAT activation and its connection to various cellular processes such as immune response, cell growth and differentiation. Understanding this could lead to better treatments for diseases involving NFAT, such as cancer and autoimmune diseases. Angiogenesis Research: Because KDR plays a crucial role in the angiogenesis process, this cell line can be used to study the mechanisms behind new blood vessel formation and help develop treatments for diseases with abnormal angiogenesis. Understanding Cell Signaling Pathways: NFAT-Luc/KDR stable cell lines can also help study intracellular signaling pathways, furthering our understanding of cellular processes and responses to various stimuli.
Ask a Question

If your question is not addressed through these resources, you can fill out the online form below and we will answer your question as soon as possible.

Customer Reviews
Reliable and consistent performance

We have been using the NFAT-Luc/KDR Stable Cell Line - HEK293T for our angiogenesis studies and its performance has been excellent. The luciferase reporter activity is consistent and reliable, providing us with reproducible results across multiple experiments.

United Kingdom

06/12/2022

Excellent sensitivity

We have tested various cell lines for our assays, and the NFAT-Luc/KDR Stable Cell Line - HEK293T stood out for its superior sensitivity in detecting NFAT-driven luciferase activity.

French

03/31/2021

Time savings in development projects

This stable cell line has greatly accelerated our research timeline. The ready-to-use nature of these cells has streamlined our workflow, allowing us to focus more on data analysis rather than cell line preparation and maintenance.

French

12/05/2022

Write a Review

Write a review of your use of Biogene products and services in your research. Your review can help your fellow researchers make informed purchasing decisions.

Needs improvement

Satisfaction

General satisfaction

Very satisfaction