Pages
Products
GFP Reporter Cell Line-A375

GFP Reporter Cell Line-A375

Cat.No. :  CSC-RR0248 Host Cell:  A375

Inquire for Price

Cell Line Information

Cell Culture Information

Safety and Packaging

Cat. No. CSC-RR0248
Description GFP Reporter Cell Line-A375 is engineered to stably overexpress GFP reporter gene. It is an ideal positive control for use in fluorescence assays. In vivo fluorescent imaging is not recommended due to high background autofluorescence.
Gene GFP
Host Cell A375
Host Cell Species Homo sapiens (Human)
Stability Validated for at least 10 passages
Reporter Type Fluorescent protein
Application

1. Gene expression studies

2. Protein localization

3. Drug screening and toxicology

4. Live cell imaging

Quality Control Negative for bacteria, yeast, fungi and mycoplasma.
Shipping Dry ice
Storage Liquid nitrogen
Revival Rapidly thaw cells in a 37°C water bath. Transfer contents into a tube containing pre-warmed media. Centrifuge cells and seed into a 25 cm2 flask containing pre-warmed media.
Mycoplasma Negative
Format One frozen vial containing millions of cells
Storage Liquid nitrogen
Safety Considerations

The following safety precautions should be observed.

1. Use pipette aids to prevent ingestion and keep aerosols down to a minimum.

2. No eating, drinking or smoking while handling the stable line.

3. Wash hands after handling the stable line and before leaving the lab.

4. Decontaminate work surface with disinfectant or 70% ethanol before and after working with stable cells.

5. All waste should be considered hazardous.

6. Dispose of all liquid waste after each experiment and treat with bleach.

Ship Dry ice
Quick Inquiry

Background

Publications

Q & A

Customer Reviews

A237 Cell Line is a human melanoma cell line that has been widely used in skin cancer research. Derived from a primary melanoma tumor, this cell line retains many of the characteristics of the original tumor, making it a valuable tool for studying the development and progression of melanoma. One of the key features of A237 Cell Line is its high level of invasive potential, which allows researchers to study the invasive behavior of melanoma cells and understand the mechanisms underlying tumor metastasis. This information is crucial for developing new strategies to prevent and treat melanoma metastasis. Additionally, A237 Cell Line has been found to have high expression levels of various oncogenes and tumor suppressor genes, making it an ideal model for studying the genetic and molecular events involved in melanoma formation. By studying these genes and their interactions, researchers can gain a better understanding of the pathogenesis of melanoma and develop new diagnostic and therapeutic methods. Furthermore, A237 Cell Line has been used in drug screening and toxicity tests. Its high invasive potential and genetic instability make it a useful model for evaluating the efficacy and safety of new anticancer drugs. A237 Cell Line is an important tool for studying melanoma, providing researchers with a model that closely resembles the characteristics of the disease in humans. Its high invasive potential and genetic instability make it a valuable resource for investigating the pathogenesis of melanoma and developing new treatments.
Customer Q&As
What is the significance of using A375 Cell Line for drug testing?

A: A375 Cell Line is significant for drug testing as it can be used to screen the effectiveness of potential anti-melanoma drugs and to study the mechanisms of action of known therapies, aiding in the development of new treatments for melanoma.

What makes A375 Cell Line unique for melanoma research?

A: A375 Cell Line is valuable for melanoma research due to its ability to grow rapidly in culture and its retention of characteristics similar to those of primary melanoma tumors.

Ask a Question

If your question is not addressed through these resources, you can fill out the online form below and we will answer your question as soon as possible.

Customer Reviews
Excellent Fluorescence

The GFP reporter cell line - A375 produces a strong and stable fluorescent signal, which is perfect for my research purposes.

French

01/17/2022

Safe and efficient

This cell line proved to be safe and efficient in my experiments, providing reliable and accurate data.

Canada

01/06/2024

Easy to use

The GFP Reporter Cell Line-A375 is easy to culture and handle, saving time and effort in my research activities.

French

07/25/2021

Value for money

The product performs well and is reasonably priced, making it a cost-effective solution for my research needs.

French

06/15/2023

Reliable and reproducible

The GFP Reporter Cell Line-A375 consistently provides reliable and reproducible results, which is essential for my research.

French

09/13/2023

Write a Review

Write a review of your use of Biogene products and services in your research. Your review can help your fellow researchers make informed purchasing decisions.

Needs improvement

Satisfaction

General satisfaction

Very satisfaction